Please use this identifier to cite or link to this item: -no DOI; please use other URI
Title: Thermocycling: enhancing efficiency of anesthetic reflectors through cyclic heating and cooling-finding the optimal temperature in a bench study
Author(s): Albrecht, Frederic
Scheffler, Kathrin
Kellner, David
Camyurdu, Ilayda
Volk, Thomas
Meiser, Andreas
Language: English
Title: Intensive Care Medicine Experimental
Volume: 14
Issue: 1
Publisher/Platform: Springer Nature
Year of Publication: 2026
Free key words: Thermocycling
Volatile anesthetics
Sevoflurane
Isoflurane
Green anesthesia
Mechanical ventilation
Sedaconda ACD-S
DDC notations: 610 Medicine and health
Publikation type: Journal Article
Abstract: Background Volatile anesthetics are widely used for sedation in intensive care. Being potent greenhouse gases, their efficient utilization is imperative. We investigated whether the efficiency of anesthetic reflection devices, such as Sedaconda ACD-S (ACD), can be improved by thermocycling, i.e., cooling the reflector during expiration and warm ing it during inspiration, and aimed to identify the optimal temperatures required. Methods A test lung connected to the ACD was ventilated under body temperature pressure saturated and nor mocapnic conditions. Isoflurane and sevoflurane were infused at rates of 0.5, 1, 2, and 5 mL/h, with sevoflurane additionally administered at 10 mL/h. For thermocycling, inspired air was heated to 37 °C by an active humidi fier without water. Cooling in steps of 26, 21, 16, 11, 6, and 1 °C was achieved by passing air from the test lung through a freezer before reaching the ACD. Results Thermocycling significantly increased concentrations of isoflurane and sevoflurane in the test lung com pared with control conditions. Cooling of the expired air led to substantial increases down to a cooling tempera ture of 16 °C; below 16 °C, further increases in concentrations were much smaller. Interpolation of our data shows that at clinically used concentrations (isoflurane: 0.4–0.6 Vol%; sevoflurane: 0.9–1.1 Vol%), consumption could be reduced by 70% (isoflurane from 2.46 to 0.74 mL/h) and 72% (sevoflurane from 5.73 to 1.60 mL/h). Reflection efficien cies—the ratio of re-inspired from exhaled anesthetic molecules in one breath—increased from around 70% to 90%. Conclusions Thermocycling significantly enhances the efficiency of volatile anesthetic reflection, offering a promis ing strategy to reduce the impact of intensive care sedation on climate change.
DOI of the first publication: 10.1186/s40635-026-00905-5
URL of the first publication: https://link.springer.com/article/10.1186/s40635-026-00905-5
Link to this record: urn:nbn:de:bsz:291--ds-480596
hdl:20.500.11880/42038
ISSN: 2197-425X
Date of registration: 17-Jun-2026
Faculty: M - Medizinische Fakultät
Department: M - Anästhesiologie
Professorship: M - Prof. Dr. Thomas Volk
Collections:SciDok - Der Wissenschaftsserver der Universität des Saarlandes

Files for this record:
File SizeFormat 
s40635-026-00905-5.pdf1,74 MBAdobe PDFView/Open


This item is licensed under a Creative Commons License Creative Commons