Bitte benutzen Sie diese Referenz, um auf diese Ressource zu verweisen: doi:10.22028/D291-46470
Titel: Tidal volume and mortality during extracorporeal membrane oxygenation for acute respiratory distress syndrome: a multicenter observational cohort study
VerfasserIn: Rixecker, Torben M.
Kühnle, Jeannine L.
Herrmann, Johannes
Lotz, Christopher
Kühn, Christian
Seiler, Frederik
Metz, Carlos
Kalenka, Armin
Mazuru, Oxana
Borchardt, Kai
Muellenbach, Ralf M.
Bals, Robert
Schmidt, Matthieu
Meybohm, Patrick
Mazuru, Vitalie
Lepper, Philipp M.
Sprache: Englisch
Titel: Annals of Intensive Care
Bandnummer: 15
Heft: 1
Verlag/Plattform: Springer Nature
Erscheinungsjahr: 2025
Freie Schlagwörter: ECMO
ARDS
Mortality prediction
DDC-Sachgruppe: 610 Medizin, Gesundheit
Dokumenttyp: Journalartikel / Zeitschriftenartikel
Abstract: Background Approximately half of the patients with acute respiratory distress syndrome (ARDS) receiving extracorporeal membrane oxygenation (ECMO) remain ECMO-dependent beyond 14 days after ECMO initiation. The identification of factors associated with mortality during an ECMO run may update prognostic assessment and focus clinical interventions. Methods In this observational study, data from 1137 patients with COVID-19 ARDS receiving ECMO support in 29 German centers between January 1st 2020 and July 31st 2021 were analyzed. Multivariable stepwise logistic regression analyses were performed to build survival prediction models with day-by-day data during the first 14 days of an ECMO run. The primary endpoint was all-cause mortality in the intensive care unit. Results Mortality in this cohort was high (75%). Patients who remained ECMO-dependent on day 14 of their ECMO run showed comparable mortality to all patients receiving ECMO support on day 1. Yet, factors associated with mortality changed during the first 14 days of ECMO support. On day 1 of ECMO support, only patient age and lactate remained in the final mortality prediction model. On day 14 of an ECMO run, tidal volume was independently associated with mortality (adjusted Odds Ratio 0.693 (95%CI 0.564–0.851), p < 0.001 for 1 mL/kg increase in tidal volume per predicted body weight). The adjusted mortality for patients with a tidal volume below 2 mL/kg on day 14 of their ECMO run was above 80% (lower limit of the 95%CI interval). Higher tidal volume was mainly based on higher respiratory system compliance. Yet, the benefit of higher compliance was not observed in some patients who were still ventilated with very low driving pressures despite remaining ECMO-dependent on day 14 of ECMO support. Conclusions Mortality predictors change during the course of an ECMO run. In a cohort with high mortality, on day 14 of ECMO support for ARDS, tidal volume may be an independent predictor of mortality. Further analyses on ventilation strategies in patients who remain ECMO-dependent are needed. Trial registration number DRKS00022964, retrospectively registered.
DOI der Erstveröffentlichung: 10.1186/s13613-025-01538-9
URL der Erstveröffentlichung: https://annalsofintensivecare.springeropen.com/articles/10.1186/s13613-025-01538-9
Link zu diesem Datensatz: urn:nbn:de:bsz:291--ds-464701
hdl:20.500.11880/40743
http://dx.doi.org/10.22028/D291-46470
ISSN: 2110-5820
Datum des Eintrags: 28-Okt-2025
Bezeichnung des in Beziehung stehenden Objekts: Supplementary Information
In Beziehung stehendes Objekt: https://static-content.springer.com/esm/art%3A10.1186%2Fs13613-025-01538-9/MediaObjects/13613_2025_1538_MOESM1_ESM.docx
Fakultät: M - Medizinische Fakultät
Fachrichtung: M - Innere Medizin
Professur: M - Prof. Dr. Robert Bals
Sammlung:SciDok - Der Wissenschaftsserver der Universität des Saarlandes

Dateien zu diesem Datensatz:
Datei Beschreibung GrößeFormat 
s13613-025-01538-9.pdf770,68 kBAdobe PDFÖffnen/Anzeigen


Diese Ressource wurde unter folgender Copyright-Bestimmung veröffentlicht: Lizenz von Creative Commons Creative Commons