Title: Evaluation of intra- and interobserver reliability in the assessment of the ‘critical trochanter angle’
Author(s): Serong, Sebastian
Schutzbach, Moritz
Zovko, Ivica
Jäger, Marcus
Landgraeber, Stefan
Haversath, Marcel
Language: English
Title: European Journal of Medical Research
Volume: 25
Issue: 1
Publisher/Platform: BMC
Year of Publication: 2020
Free key words: Critical trochanter angle
Total hip arthroplasty
Stem alignment
Intraobserver
Interobserver
Reliability
DDC notations: 610 Medicine and health
Publikation type: Journal Article
Abstract: Background: The recently described 'critical trochanter angle' (CTA) is a novel parameter in the preoperative risk assessment of stem malalignment in total hip arthroplasty. As its reproducibility needs to be evaluated, the given study aims to investigate intra- and interobserver reliability. It is hypothesized that both analyses justify the clinical use of the CTA. Methods: A total of 100 pelvic radiographs obtained prior to total hip arthroplasty were retrospectively reviewed by four observers with different levels of clinical experience. The CTA was measured twice by each observer at different occasions in the previously described technique. Intra- and interobserver reliability was evaluated using intraclass correlation coefficients (ICC) with confidence intervals (CI) and the Bland-Altman approach. Results: The mean CTA in both measuring sequences was 20.58° and 20.78°. The observers' means ranged from 17.76° to 25.23°. Intraobserver reliability showed a mean difference of less than 0.5° for all four observers (95% limit of agreement: - 7.70-6.70). Intraobserver ICCs ranged from 0.92 to 0.99 (CI 0.88-0.99). For interobserver variation analysis, ICCs of 0.83 (CI 0.67-0.90) and 0.85 (CI 0.68-0.92) were calculated. Conclusion: Analyses concerning intra- and interobserver reliability in the assessment of the CTA showed 'very good' and 'good' results, respectively. In view of these findings, the use of the CTA as an additional preoperative parameter to assess the risk of intraoperative stem malalignment seems to be justified.
DOI of the first publication: 10.1186/s40001-020-00469-4
Link to this record: urn:nbn:de:bsz:291--ds-333322
hdl:20.500.11880/30981
http://dx.doi.org/10.22028/D291-33332
ISSN: 2047-783X
Date of registration: 29-Mar-2021
Faculty: M - Medizinische Fakultät
Department: M - Orthopädie
Professorship: M - Prof. Dr. Stefan Landgraeber
Collections:SciDok - Der Wissenschaftsserver der Universität des Saarlandes

Files for this record:
File Description SizeFormat 
4-Evaluation_of_intra-_and_interobserver_reliability.pdfArtikel996,53 kBAdobe PDFView/Open


This item is licensed under a Creative Commons License Creative Commons